HOLIS Sample Test Case 01: Test Control Light | R EVISION H ISTORY | | Date | Revision | Description | Author | | 4/14/03 | 1.0 | First draft | Luis R. | | 4/15/03 | 1.1 | Correction to increase/decrease rate | Bob S. | | | | | | Description This test case, used to test instances of the use case Control Light, is used only to test dim-enabled Control Switch buttons that have been preassigned to a light bank. Note Run the test case multiple times and with different lengths of hold-button time to verify that the system is restoring OnLevel properly. | Test Case ID | Scenario | Description | Condition: Button Pressed < Timer Period | Condition: Button Pressed > Timer Period | Condition: Button Released After Being Held | Condition | Expected Result | | 1 | 1 | Basic flow: Resident releases button before timer period ends | < 1 sec. in .1-sec. intervals | I | N/A | Light on | Light goes off | | 2 | 1 | Basic flow: Resident releases button before timer period ends | < 1 sec. in .1-sec. intervals | I | N/A | Light off | Light goes on | | 3 | 2 | Alternate flow: Resident continuously presses button for longer than timer period | I | 1 “60 sec. | N/A | N/A | Light level goes up and down continuously | | 4 | 3 | Resident releases switch after continuously pressing button | I | I | V | N/A | Light stays at last brightness | HOLIS Sample Test Case 02: Test Round-Trip Message Protocol | R EVISION H ISTORY | | Date | Revision | Description | Author | | 4/14/03 | 1.0 | First draft | Adrienne | | | | | | | | | | | Description This test case tests the round-trip message protocol between the CCU and the Control Switch according to the requirements defined in the CCU Supplementary Specification. This test case tests the following requirements from the CCU and Control Switch Supplementary Specifications. | CCU Supplementary Specs | Control Switch Supplementary Specs | | SR4, SR4.1, SR4.2, SR4.3, SR4.4 | CSSR88, CSSR91 “97, CSSR100 “107 [*] | [*] Note to file: The table above can be deleted after the traceability matrix is established. To minimize maintenance, the trace matrix is the only place we will maintain these links. Events | Test Case ID | Event Description | Input 1 | Input 2 | Expected Result | | 5300 | Press switch button 0 on Control Switch 1 and initiate message from CS to CCU. | Button only | | CCU message-received indicator is lit, and CS message-received indicator is lit. | | 5301 | Examine received message in diagnostic line of CCU display. | | | [01][01][01][5A] | | 5302 | Examine sent message in CCU display. | | | [55][FF][01][F7] | | 5303 | Press Control Switch buttons 0 “5 simultaneously and hold for 3 seconds. | All buttons depressed 3+ seconds | | CCU message-received indicator is lit. Three messages should be in the message display buffer. | | | Examine message 1. | | | [01][01][3F][3C] | | | (Remainder of test case deleted for brevity.) | | | | |